Typical transmission time per byte
Supply voltage
Maximum permitted current consumption
Maximum permitted current consumption via
DI/DQ interface
Current consumption (on standby), typical
Current consumption (at 400 mW transmit power), typical
Interfaces
Antenna connectors
Power supply
DI/DQ interface
Digital inputs
Digital outputs
Ethernet interface
Mechanical specifications
Material
Color

SIMATIC RF600

System Manual, 06/2019, J31069-D0171-U001-A22-7618
Write access
Read access
< 20 °C
≃ 55 °C
20 V input voltage on the reader
24 V input voltage on the reader
30 V input voltage on the reader
20 V input voltage on the reader
24 V input voltage on the reader
30 V input voltage on the reader
2 ms
0.15 ms
24 V DC (20 ... 30 V DC)
0.3 A
0.5 A
0.33 A
200 mA / 4 W
170 mA / 4.1 W
150 mA / 4.2 W
260 mA / 5.2 W
220 mA / 5.3 W
170 mA / 5.1 W
1x RP-TNC
1x M12 (8-pin)
1x M12 (5-pin)
1
1
1x M12 (4-pin), 100 Mbps
Pocan (silicone-free)
TI-Grey
Readers
5.3 SIMATIC RF615R
6GT2811-6CC10-xAA0
2)