Permitted ambient conditions
Ambient temperature
•
•
•
Distance from metal
Degree of protection
Resistance to mechanical stress
Shock-resistant according to DIN EN 60721-3-7,
Class 7 M3
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (L x W x D)
Weight
Standards, specifications, approvals
Proof of suitability
MTBF
The information relates to the maximum read range. You will find more information on
1)
ranges in the section "Minimum distances and maximum ranges (Page 55)".
The values for shock and vibration are maximum values and must not be applied
2)
continuously.
Note
Effects of temperatures > 70 °C
Note that in temperature ranges > 70 °C, the transponder can become slightly deformed.
However, this has no effect on the transponder function.
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
7.6 SIMATIC RF610T ATEX
-25 ... +85 °C
•
-40 ... +85 °C
•
-40 ... +85 °C
•
Not suitable for mounting directly on metal
IP67
Torsion and bending stress conditionally permis-
sible
100 g
2)
50 g
2)
86 × 54 × 0.4 mm
3 g
TÜV 11 ATEX 081778 X
(EN 60079-0, EN 60079-11):
II 3 G Ex ic IIB T6/T5/T4 Gc,
II 3 D Ex ic IIIB T
120°C Dc,
5
-25 °C < Ta < +85 °C
1712 years
Transponder
6GT2810-2BB80-0AX1