Technical Specifications - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Transponder
7.11 SIMATIC RF645T
Delivery format
The SIMATIC RF645T is supplied in the following form:
● 20 transponders per packaging unit
Minimum order quantity: 1 packaging unit (20 units)
The mounting cover for SIMATIC RF645T is supplied in the following form:
● Minimum order quantity: 1 packaging unit (20 units)
The retaining bracket for SIMATIC RF645T is supplied in the following form:
● Minimum order quantity: 1 packaging unit (20 units)
7.11.3

Technical specifications

Table 7- 44
Product designation
Radio frequency
Operating frequency (broadband)
Memory
Chip (manufacturer/type)
Memory configuration
Number of write cycles (< 40 °C)
Number of read cycles (< 40 °C)
Data retention time (< 40 °C)
Electrical data
Read range (on the metallic support)
Protocol
Transmission speed
Polarization
436
Technical specifications of SIMATIC RF645T
ETSI
FCC, CMIIT and others
EPC
User memory
TID
SIMATIC RF645T
865 to 868 MHz
902 to 928 MHz
NXP / UCODE 7xm-2k
56 bytes / 448 bits
256 bytes / 2048 bits
12 bytes / 96 bits
> 100 000
> 10
14
20 years
≤ 6 m
1)
ISO 18000-63
≤ 320 kbps
Linear (long side = polarization axis)
System Manual, 06/2019, J31069-D0171-U001-A22-7618
6GT2810-2HC05
SIMATIC RF600

Advertisement

Table of Contents
loading

Table of Contents