Global Settings - Siemens SINUMERIK 840Di sl Function Manual

Eps network services
Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

3 Setting up functions

3.5 Global settings

3.5 Global settings
3.5.1 Setting the notification limit
Description of functions
The notification limitation function enables a repeated delay to be set for the
specifiable time span, during which no notifications are sent after the initial one.
This prevents, for example, a glut of alarms being output in the event of a faulty
configuration, or trigger signals.
Fig. 3-47: Setting the notification limit
Field
Status
Do not send any
messages for ...
Note
When the notification limit is active, all events are recorded in the event history.
However, the first notification is sent within the set time window in order to
prevent, if necessary, an overflow in the mailbox.
3.5.2 PLC and NC settings
Description of functions
To be able to use PLC triggers, PLC conditions, and PLC traces on a machine, the
data blocks for the machine used in the control must be made known and
performance enabled for the ePS Network Services functions.
Feedback messages must be configured (data format) in order for them to be sent
to the PLC via DB10 DBB118 to DBB121 in a SINUMERIK and a freely
configurable data block area in a SIMATIC.
3-148
Content
Switching the notification limit for the machine on/off.
Note:
This setting is activated immediately after storage of a
change.
Time for notification limitation
1 to 1440 minutes
1 to 24 hours
ePS Network Services, Function Manual (FH) - Release 12/2008
© Siemens AG 2008 All Rights Reserved
12/2008

Advertisement

Table of Contents
loading

Table of Contents