12/2008
Feedback to the PLC
Field
DB10.DBB118
or indiv. data element
DB10.DBB119
or indiv. data element
DB10.DBB120
or indiv. data element
DB10.DBB121
or indiv. data element
The S7 data types and formats should be taken from the manual titled
"Programming with STEP 7 V5.4" (in the Appendix "Data and parameter
types").ePS Network Services does not support times or real numbers here.
The S7 data type is also determined by means of the data width. If a word is
defined, the following byte is, therefore, included automatically and blocked for a
separate format. If a double word is defined, all 4 bytes are assigned as double
words. ePS Network Services checks the plausibility of the potential formats and
only permits correct configurations (e.g. data word 121 is not permitted).
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 12/2008
Content
Determine the S7 data type and S7 format for the data
type, with a label for the content of these variables.
Determine the S7 data type and S7 format for the data
type, with a label for the content of these variables.
Determine the S7 data type and S7 format for the data
type, with a label for the content of these variables.
Determine the S7 data type and S7 format for the data
type, with a label for the content of these variables.
3 Setting up functions
3.5 Global settings
3-151