Modes and Settings

To operate the PROFIBUS ILM, the terminating resistor, the data rate and the monitoring options must
be set manually.
Note:
When shipped, the configuration is as follows:
â
The terminating resistor is inactive
â
The data rate is set to 1.5 Mbps
â
The "monitor link with acknowledgment pulse" monitoring mechanism is inactive.
â
The activation of the signaling contact is disabled.
The settings can be made after removing the cover from the basic module using switches S201 (transmission
rate and monitoring mechanisms) and S202 (terminating resistor).
Terminating resistor switch
(S202)
ON
OFF
Plug connector for ribbon cable
PROFIBUS
attachments
Figure 6:
Elements for Setting the Configuration of the PROFIBUS ILM
Configuration switch (S201)
0
1
1
1
Power supply and signaling contact
Cable for power supply
PROFIBUS cable
and signaling contact
21
Infrared Link Modul (ILM)
Cable clamps for
contacting the shield