Siemens SINUMERIK 840Di sl Function Manual page 149

Eps network services
Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

12/2008
An AC marker must be configured in order to perform axis tests.
Fig. 3-48: Set up PLC for control monitors
Field
Trigger
configurations
Monitor
configurations
Monitor data
PLC performance
index
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 12/2008
Content
Number of the data block for PLC trigger
configurations (number only; without DB)
Number of the data block for PLC trace
configurations (number only; without DB)
Number of the data block for PLC trace
data (number only; without DB)
It is possible to use the PLC performance
index in order to limit the number of PLC
functions executed by ePS Network
Services, to prevent ePS Network
Services from overloading the control
unnecessarily.
The cycle time allocated to each ePS
Network Services function is directly
proportional to the number of ePS
Network Services functions executed.
Since there are different PLCs with
different command execution times, a
sensible quantity must be determined for
this index.
3 Setting up functions
3.5 Global settings
Type
Display and input
Digits from 0 to 9999
Display and input
Digits from 0 to 9999
Display and input
Digits from 0 to 9999
PLC performance index
Display and input
Digits from 1 to 100
3-149