downloaded data covers.
6
There are three formats you can view or export the downloads
in: a comma delimited (.csv) file, a Microsoft Excel file, or a
Wavetronix-specific text format that opens in a text editor like Note-
pad. To view the downloaded data, click the desired format's icon on
the View: (choose format) line.
7
To export the downloaded data, click the checkbox next to your
desired format on the Export: (choose format & location) line.
Click the magnifying glass icon to change where to save the file, if
desired, and then click Export.
Push
Access the Push screen by clicking the Push button on the Data screen.
This function lets you push data from the sensor without waiting for a
request from SSMHD. You can push event, interval or presence data.
Enabling data push
1
Choose which kind of data you want to push, then click on the cor-
responding tab: Event, Interval or Presence.
Click the Enabled checkbox.
2
3
Choose which port you want to push the data on, RS-485 or RS-232.
Be aware that both of these are half-duplex, meaning that they can't
send and receive data at the same time. If you use one of these ports
Figure 90. Push screen
Chapter 9: Setting Up and Downloading Sensor Data
Note. You can set
the sensor to push
multiple kinds of
data at the same
time, but if you do,
set them to push
on different ports.