Set Display IDs in the Displays

WallNet does not go out and seek the display IDs.
You must list them for WallNet. But first you must
set them with the remote control in each display.
Set the IDs so that each display has a unique
combination of Group ID and Unit ID in that wall.
The displays respond when they are addressed
individually. You don't want two displays
responding at the same time.
The display model User Guide has more detail
about setting the IDs and connecting the displays
for RS232 control. In general, the following steps
will work for most products, except Clarity Matrix.
1
2
3
4
5
6
7
The baud rate is not automatically adjusted, as
when modems talk to each other and find the high-
est rate they can both use. The baud rate must be
set manually at all the displays and set manually in
WallNet.
Using the remote control, press
open the menu system on your display.
Select
ADVANCED OPTIONS
.
ENTER
Select
SERIAL PORT SETTINGS
.
ENTER
Select
GROUP ID
+ / – keys to scroll through the
alphanumeric characters.
Select the baud rate you want to use. This is
the baud rate between the WallNet box and
the displays. All displays must be set to the
same baud rate.
Press
to save your changes.
PREV
Press
to close the menu system on
MENU
your display.
Set Display IDs in the Displays
and press
and then
UNIT ID
to
MENU
and press
. Use the