Komatsu ecot3 PC300LC-8 Shop Manual page 451

Hydraulic excavator
Table of Contents

Advertisement

30 Testing and adjusting
Default (Breaker Detect)
Check or change various settings related to the
machine monitor and machine by "Default".
The function of setting breaker automatic judgment
is used to set the display to give warning when the
breaker is used in an improper working mode.
1.
Selecting menu
Select "Default" on the "Service Menu" screen.
2.
Selecting sub menu
After the "Default" screen is displayed, select
"Breaker Detect" with the function switches or
numeral input switches.
a Select this item similarly to an item on the
"Service menu" screen.
PC300, 350-8
3.
Selecting display setting
After the "Breaker Detect" screen is displayed,
select the setting with the function switches.
[F3]: Move to lower item
q
[F4]: Move to upper item
q
[F5]: Cancel
q
Default screen
[F6]: Confirm selection and return to
q
Default screen
a When the machine is delivered, Disable is
set.
a Display of "Breaker Detect"
SEN02626-04
selection
and
return
to
45

Advertisement