Komatsu ecot3 PC300LC-8 Shop Manual page 152

Hydraulic excavator
Table of Contents

Advertisement

SEN01994-01
3.
Pressure compensation valve area ratio
Function
q
The state of division changes according to the
area ratio of pressure compensation portion
(A1) and (A2). Area ratio = (A2)/(A1)
If area ratio = 1 : the spool meter-in down-
q
stream pressure will be equal to the maximum
load pressure, and the pressure will be divided
according to the opening area ratio.
q
If area ratio = 1 or over : the spool meter-in
downstream pressure will be greater than the
maximum load pressure, and the pressure will
be divided smaller than the opening area ratio.
q
If area ratio = 1 or under : the spool meter-in
downstream pressure will be smaller than the
maximum load pressure, and the pressure will
be divided greater than the opening area ratio.
26
10 Structure, function and maintenance standard
PC300, 350-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecot3 pc300-8Ecot3 pc350lc-8Ecot3 pc350-8

Table of Contents