Komatsu ecot3 PC300LC-8 Shop Manual page 325

Hydraulic excavator
Table of Contents

Advertisement

10 Structure, function and maintenance standard
KOMTRAX terminal
Model: TH300
q
The KOMTRAX system uses satellite communication technology.
1.
Communication antenna connection
2.
Machine harness connection (AMP-14P)
3.
Machine harness connection (AMP-10P)
Input and output signals
AMP-14P [CN-CK01]
Pin No.
Signal name
A-1
Electric power supply (12 V)
A-2
NC (*)
A-3
NC (*)
A-4
Electric power supply switching
A-5
NC (*)
A-6
NC (*)
A-7
GND
A-8
GND
A-9
NC (*)
A-10 NC (*)
A-11 NC (*)
A-12 NC (*)
A-13 NC (*)
A-14 NC (*)
*: Never connect to NC, or malfunctions or failures will
occur.
AMP-10P [CN-CK02]
Pin No.
Signal name
B-1
Serial signal DCD
B-2
Serial signal RXD
B-3
Serial signal TXD
B-4
Serial signal DTR
B-5
Serial signal SGND
B-6
Serial signal DSR
B-7
NC (*)
B-8
NC (*)
B-9
NC (*)
B-10 NC (*)
*: Never connect to NC, or malfunctions or failures will
occur.
PC300, 350-8
Outline
q
This terminal sends various machine informa-
tion based on the network signals and input
signals obtained through the machine monitor,
as well as GPS position data, via wireless
communication. This terminal can send infor-
mation via communication antenna.
Input/output
q
Conditions of this terminal can be checked with
Input
the "KOMTRAX Settings" in the service mode
of the machine monitor.
q
This terminal cannot be used in the countries
Output
or territories where it is not authorized by the
law.
a When starting to use the KOMTRAX system or
changing the country where it is used, you are
required to notify the country where it will be
used in advance.
a When using the KOMTRAX system in Japan,
the terminal special to Japan must be installed.
Input/output
Output
Output
Input
Input
Output
SEN01998-05
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecot3 pc300-8Ecot3 pc350lc-8Ecot3 pc350-8