10 Structure, function and maintenance standard
1.
Breaker setting selection screen.
q
On this screen, you can allocate one of
two set flow rates as a flow rate in breaker
mode.
q
The B symbol is displayed before items
specified to breaker mode.
a The defaults of both flow rates are 230 l/
min.
F3 : Selects (highlights) an item one down.
F4 : Selects (highlights) an item one up.
F5 : Returns to the breaker setting menu
screen.
F6 : Specifies the selected (highlighted) item
as a flow rate in breaker mode.
2.
Breaker flow rate setting screen
q
On this screen, you can specify a flow
rate.
The B symbol is displayed before items
q
specified to breaker mode.
F3 : Selects (highlights) an item one down.
F4 : Selects (highlights) an item one up.
F5 : Returns to the breaker setting menu
screen.
F6 : Switches to the flow rate level setting
screen for the selected (highlighted) item.
PC300, 350-8
q
On the flow rate level setting screen,
change the set flow rate.
F3 : Decreases the flow rate.
F4 : Increases the flow rate.
F5 : Returns to the flow rate setting screen
without changing the flow rate.
F6 : Returns to the flow rate setting screen
after specifying the flow rate.
Flow level
Flow rate (l/min)
15
273
14
250
13
240
12
230
11
220
10
210
9
200
8
190
7
180
6
170
5
160
4
150
3
140
2
130
1
120
Changing attachment mode setting
q
Selecting ATT on the breaker/attachment set-
ting screen switches to the 2-way attachment
setting menu. On this screen, select the
attachment setting screen or breaker flow rate
setting screen.
SEN01998-05
Remarks
Default
55