Sof twa re Out puts 7, 8, 9 and 10 (ava i la ble for this ap -
pli ca tion) must be: Mo no sta ble and Nor mally open
(DO NOT pro gram the se Out puts as Re ser ved).
The ON Time of the Out put de ter mi nes how long the
"Vo i ce Mo du le" will stay ON af ter ac ti va tion, the re fo re,
must be long eno ugh to al low the User to Li sten-in on
the lo ca tion. Each Out put, con nec ted as shown in the
wi ring dia gram (Fi gu re 4) will be able to con trol one
"Vo i ce Mo du le".
Use the Par ti tion and/or Con trol pa nel Events in the
Event-Actions page to ac ti va te the Dial ler and Te lep ho -
ne Com mu ni ca tor Out puts. In this way, the zone events
will be ava i la ble for "Vo i ce Mo du le" ma na ge ment. Pro -
gram the zone events (re le vant to the lo ca tion con cer -
ned) to ac ti va te the Out put that con trols the re spec ti ve
"Vo i ce Mo du le". Re pe at this pro ce du re for the ot her
Out puts, as re qui red.
Upgra de Fir mwa re Au to-se lect mode will al low the User
(du ring a dial ler call) to ac ti va te Re mo te li sten-in on the
lo ca tion that ge ne ra ted the Alarm.
*
Connect ONLY the [+] terminals of the
VOX-REM board to the terminal [+12] of
the Voice Board.
OC1
OC2
OC3
Omnia/4R
RL1
RL2
SP-
SP+
MIC
st
1 Voice module
Fi gu re 4 Wi ring for Ma nual-se lect Li sten-in mode
KYO320
M-IN/OUT Exp.01
T1
OC4
+12
RL3
RL2
SPK-
*
SP-
SP+
MIC
nd
2 Voice module
n Manual and Auto-select mode
Ma nual and Auto-se lect Li sten-in can be in te gra ted.
This will al low the User to se lect (ma nually) spe ci fic lo -
ca tions du ring standby sta tus.
Use 4 Out puts for Ma nual-se lect Li sten-in mode, and 4
Out puts for Auto-se lect li sten-in mode.
The Out puts must be con nec ted in two's — one Ma nual
and one Auto, as shown in Fi gu re 4.
To en su re pro per fun ctio ning of Auto-se lect mode, the
ma nually con trol led Out puts must be in standby sta tus.
The re fo re, the Out puts must al ways be re sto red to
Standby when a ma nually con trol led li sten-in ses sion
ends.
programmed
as Output
T2
T3
T4
+F
Voice board
SPK+
MIC
+12
*
SP-
SP+
MIC
rd
3 Voice module
APPENDIX
M-IN/OUT Exp.02
programmed
as Input
T1
T2
T3
T4
OC1
OC2
OC3
OC4
+12
Omnia/4R
RL1
RL2
RL3
RL2
*
*
SP-
SP+
MIC
th
4 Voice module