2. Fix the Mo du le to the base of the con trol unit using
the screws sup plied, ma king sure it is cor rectly ali -
gned with the screw an chor ho les (144).
3. Con nect the Mo du le con nec tor (130) to the con trol
unit se rial port (143) using the PC-Link ca ble sup -
plied (140).
4. Con nect con nec tor (132) to the LAN using an
Ether net ca ble.
+
Use a ca te gory 5 (or bet ter) shiel ded Ether net ca -
ble (STP or FTP).
5. Whe re pre sent, con nect the [OC] ter mi nal to ter mi -
nal block (134).
6. Con nect ter mi nals [+V] and [M] on the ter mi nal
block (134) to the cor re spon ding ter mi nals [+B4]
and [M] on the con trol unit mot her bo ard (142).
7. Re con nect the con trol unit to the po wer supply.
8. Pro gram the K-NET Mo du le as de scri bed in the
"Pro gram ming" sec tion of the K-NET ma nual.
n Technical Specifications
The fol lo wing ta ble con ta ins the tec hni cal spe ci fi ca tions
of the K-NET Mo du le.
Voltage
Current draw
Standby current
Operating Temperature
Dimensions (W x H x D)

Reset default

To re set the fac tory de fa ult pro gram ming (see the
Instal la tion Ma nual Vol.1) :
1. Re mo ve all po wer from the Con trol pa nel (Ma ins
and bat tery).
2. Re mo ve the jum per 21 (M).
3. Wait at le ast 20 se conds.
4. Re pla ce the jum per 21 (M).
EVENT
Tab le 12 Struc ture of the main Re porting for mats sup ported by the Sys tem (con tin ued ...)
46
9.6 ÷ 27.6 V_
250 mA
50 mA
-5 ÷ +40 ° C
95 x 65 mm
Alarm on zone
Tamper on zone
Fire alarm on partition
24h alarm on partition
5. Re set the po wer supply to the Con trol Pa nel (see
"Con nec ting
"INSTALLATION" chap ter in the Instal la tion Ma -
nual, Vol.1).
!
Jum per 21 (M) must be di scon nec ted for at le -
ast 20 se conds in or der to en su re full re set of
the fac tory de fa ult pro gram ming, and to avo id
pro blems that may oc cur when the po wer
supply is re sto red.
Installer code locked If the Lock Instal ler code op -
tion is ena bled, the Instal ler PIN will not be able to re set
to fac tory de fa ult (re fer to Lock Instal ler code in the
Options sec tion in the Instal la tion Ma nual Vol.1).

Reporting Formats

This pa ra graph de scri bes the struc tu res of the main re -
por ting for mats sup por ted by the system.
n TELIM
The TELIM pro to col tran smits as fol lows:
Ø User Code (4 di gits — 0 thro ugh 9);
Ø Event Code: 41 in the event of Alarm or Tam per on the
first 16 zo nes of the Con trol pa nel, 0 in all ot her ca ses;
Ø 2 byte (16 bit) re pre sen ting the sta tus of the first 16
zo nes — 0 Standby; 1 = Alarm or Tam per.
n Contact ID
Con tact ID tran smits as fol lows:
Ø User Code (4 he xa de ci mal di gits — 0 thro ugh F );
Ø Qua li fier: 1 = new event or Di sar ming ope ra tion; 3
event re sto re event or Arming ope ra tion
Ø Class Code (CL. co lumn): iden ti fies the type of
event (Alarm, Tro u ble, Fire, etc.);
Ø Event Code (CODE co lumn): iden ti fies the event
(Event Co des can be chan ged, re fer to "Actions" un -
der "Di gi tal Com mu ni ca tor" in the "PROGRAMMING"
sec tion in the Instal la tion Ma nual Vol.1);
Ø Gro up Num ber (GROUP co lumn), whe re pos si ble,
iden ti fies the Par ti tion of the "ob ject" which ge ne ra -
ted the event;
Ø Zone Num ber (ZONE co lumn), whe re pos si ble,
iden ti fies the "ob ject" (Zone, Code, Key, etc.) which
ge ne ra ted the event.
n SIA/SIA over B-NET
SIA/SIA over B-NET is a FSK (Fre quency Shift Ke ying)
for mat, that tran smits al ter na ti vely in two slightly dif fe rent

CONTACT ID

CL. CODE GROUP
1
30
00
1
37
00
1
10
part. no.
1
33
part. no.
a
Po wer
Supply"
SIA
st
ZONE
TYPE
1
zone no.
BA/BR
0000
zone no.
TA/TR
0000
000
FA/FR
part. no.
000
BA/BR
part. no.
in
the
nd
2
zone no.
zone no.
000
000