N.
3415
Memo message present
3416
B-NET module missing
3417
Lan Link missing
3418
IP receiver missing
Ta bel la 7 Spe cial events for KYO320.

Events - Actions

From the Pro gram ming menu:
PROGRAMMING
Configuration
1. Using A or B, se lect Event -> Action:
PROGRAMMING
Even t
à Action
2. Press ENTER:
Even t à
Actio n
Even t n.
0001
3. Enter the Event ID num ber, then press ENTER.
+
NOTE: The Event ID num bers can be fo und in the
No. co lumn of the Event ta bles. For events that re -
gard system ele ments such as: Zo nes, Par ti tions,
Out puts, Co des, Key pads, Keys/Cards and Re a -
ders, you must add the ID num ber of the ob ject to
the Event ID num ber shown in the Event No. co -
lumn. EXAMPLE: The Event ID num ber of Bur -
glar alarm on par ti tion 1 is 0753 (i.e. 0752 +
par ti tion 1 = 0753), whe re as, the Event ID num ber
of Bur glar alarm on par ti tion 6 is 0758 (i.e. 0752
+ par ti tion 6 = 0758).
Even t
n.
0001
Output
____
4. Enter the ID num ber of the Out put as so cia ted with
the se lec ted event (en ter all ze ros for NO Out put), then
using A or B, se lect Dig.Com.On.
Even ts n.
0001
Dig.Com.
On ___
5. Enter the ID num ber of the Di gi tal Com mu ni ca tor ac -
tion the Con trol pa nel must per form when the se lec ted
event oc curs (en ter all ze ros for NO ac tion), then using
A or B, se lect Dig.Com.Off.
Even ts n.
0001
Dig.Com.
Off___
6. Enter the ID num ber of the Di gi tal Com mu ni ca tor ac -
tion the Con trol pa nel must per form when the se lec ted
KYO320
EVENTO
PROGRAM PANEL
event ends (en ter all ze ros for NO ac tion), then using A
or B, se lect Dial ler On.
Event
n.
0001
Dial ler On
___
7. Enter the ID num ber of the Dial ler ac tion which the
Con trol pa nel must per form when the se lec ted event
oc curs (en ter all ze ros for NO ac tion), then using A or
B, se lect Dial ler Off.
Even t n.
0001
Dialler Off
___
8. Enter the ID num ber of the Dial ler ac tion which the
Con trol pa nel must per form when the se lec ted event
ends (en ter all ze ros for NO ac tion), then press ENTER
to go back to step 3.
Event setup
The Event se tup op tion will al low you to pro gram the
Event Types to be sto red in the Log ger and/or prin ted
in real time (re fer to"Log ger – Set ting up events" un der
"Pro gram ming").
PROGRAMMING
Configuration
1. Using A or B, se lect the Event se tup op tion.
PROGRAMMING
Event setup
2. Press ENTER:

Even t setup 001

Zone Alarm
3. Using A or B, se lect the re qui red Event Type, or en -
ter the Event Type ID num ber (3 di gits, see NOTE),
then press ENTER.
+
NOTE: The Event Type ID num bers can be fo und
in the No. co lumn of the Event Type ta bles.
For Event Types with 2 di git ID num bers, you must
en ter zero (0) fol lo wed by the 2 di git ID num ber.
Zone Alarm
Log enabled
x
4. Using A or B, se lect the Log ena bled op tion (re fer
to "") or Prin ter ena bled op tion (re fer to "Prin to ut").
Press ON or OFF to ena ble or di sa ble the op tion con -
cer ned, then press ENTER and go back to step 3.
31

Advertisement

Table of Contents
loading

Table of Contents