n Programming Alarm zones
Work ca re fully thro ugh the fol lo wing steps.
Zone Type
Instan t
x
7a. Using A or B, se lect the Zone type (Instant, Entry
de lay, Entry path, Exit de lay, Last exit, 24 ho urs,
Fire or Du ress). The zone types that will be ava i la ble
de pend on the zone set tings.
Using ON or OFF, ena ble/di sa ble the se lec ted zone
type ("û" me ans ena bled, and "-" di sa bled), press
ENTER to go to the next step.
Zone Attri bu te
Unbypas sable -
7b. Using A or B, se lect the zone at tri bu te (Unbypas -
sa ble, Chi me, Test, Au tob ypas sa ble, Au tobyp.+re -
inc. (re fer to "Au tob ypass with re set unbypass"), Stay,
De lay on part. (re fer to "De la yed on stay ar ming"),
Del&Est. r.t.a. (re fer to "De la yed and esti ma ted on re -
ady to arm"), Disp.Entry Time (re fer to "Di splay du ring
Entry Time"). The at tri bu tes that will be ava i la ble de -
pend on the zone set tings.
Using ON or OFF, ena ble/di sa ble the se lec ted zone at -
tri bu te "û" me ans ena bled, and "-" di sa bled), then
press ENTER to go to the next step.
8b. Using A or B se lect, in this sec tion, the zone at tri bu -
tes "Vi bra tion" and "Rol ler Blind" (for the first eight zo -
nes ONLY)
Zone Attri bu te
Roller Blind
Using ON or OFF, ena ble/di sa ble the se lec ted zone at -
tri bu te "Vi bra tion" and "Rol ler Blind" , "û" me ans ena -
bled, and "-" di sa bled). Re fer to fol lo wing Ta ble for
ot her pa ra me ters re le vant to Zo nes with the 'Rol ler
Blind' at tri bu te.
Times/
1
2
3
Pulses
30 s
0
1
2
2 min.
7
8
9
4 min.
14
15
16
Always
21
22
23
Exam ple: for 3 PULSES and 4 MINUTES, you must set
a va lue of 16.
To set the two at tri bu tes of a "Vi bra tion" zone
Vibration
Sen si tivityà
Set the sen si ti vity va lue from 0 up to 30, and the Pul se
va lue from 1 up to 7.
Vibration
Pulses
0
22
4
5
6
3
4
5
10
11
12
17
18
19
24
25
26
00
9. press ENTER.
Cycles
Repetitive
7c. Enter the re qui red num ber of cycles, or en ter all ze -
ros to set Re pe ti ti ve, then press ENTER and go to step
8c.
8c. This pa ra me ter de ter mi nes the num ber of ti mes the
zone will ge ne ra te the Alarm on zone event.
Va lid en tries: Cycles from 1 to 254 or Re pe ti ti ve.
If the zone is a Glass Bre ak zone, the Cycles pa ra me -
ter will be for ced to 1.
n Pro gram ming Com mand zones
If you se lec ted Com mand at step 6, work ca re fully
thro ugh the fol lo wing steps.
Select command
Toggle arm/dis x
7d. Using A or B, se lect the Action/s that will be ge ne -
ra ted by the Com mand zone (Tog gle arm/dis. (re fer to
"Arm/Di sarm/Tog gle"), Hard arm/dis. (re fer to "Arm/Di -
sarm hard"), Arm only, Di sarm only, Par ti tion re set,
Pa nel re set, Del.tel.que ue (re fer to "Cle ar call que ue").
8. Using ON or OFF, ena ble/di sa ble the se lec ted
Action/s ("û" me ans ena bled, and "-" di sa bled), then
press ENTER.
The Alarm Mes sa ges sec tion is for Alarm and Com -
mand zo nes.
Alarm mes.n. ---
None
This pro gram ming sec tion will al low you to as sign two
vo i ce mes sa ges (from the 64 ava i la ble) to the zone con -
cer ned. You can as sign one mes sa ge to
tus and the ot her to Alarm sta tus.
If you se lect "None" in the Alarm Mes sa ge field, Alarm
sta tus will be si gnal led by two Be eps, when the system
7
is ac ces sed over the pho ne.
If you se lect "None" in the Standby Mes sa ge field,
6
Standby sta tus will be si gnal led by one Beep, when the
13
system is ac ces sed over the pho ne.
20
9. Using A or B, se lect the mes sa ge num ber or "None",
27
then press ENTER.
Stdby mes.n. ---
None
For the Standby mes sa ge, re pe at step 9, then press
ENTER.
10. The Par ti tions pa ra me ter as su mes dif fe rent me a -
nings for Alarm zo nes and Com mand zo nes.
Par ti tion
x
Standby sta -
1-8
KYO320