If work has to be performed on the cleaning device while it is being supplied with voltage
and/or compressed air:
► keep your body, especially your hands, face, hair, any objects and all clothing away
► wear ear protection
► wear protective goggles with side protection
A cleaning cutter that has become very hot through use can cause severe burns.
Before handling cleaning cutters, allow cleaning cutter to cool to room temperature (+25°C,
+77 °F).
Ensuring that the
Attempt to briefly activate the cleaning device without any compressed air supply to check
cleaning device is
whether the cleaning device is depressurised. Proceed as follows:
depressurised
1
2
Robacta Reamer V Easy and Robacta Reamer V Easy Han6P J:
3
-
-
Robacta Reamer V:
3
-
-
90
from the cleaning cutter, cleaning motor, lifting device, gas nozzle clamping device,
wire cutter and parting-agent injection nozzle
CAUTION!
Take protective measures:
-
The cleaning cutter, lifting device, gas nozzle clamping device, wire cutter and
parting-agent injection nozzle could start up. Therefore keep your body, especial-
ly your hands, face and hair, any objects and all clothing away from the compo-
nents referred to above
-
Wear ear protection
-
Wear protective goggles with side protection
Ensure that the cleaning device has been disconnected from the compressed air sup-
ply
Briefly turn the "Cleaning" screw on the cleaning device 90° to the right, then turn it
straight back to its original position
If the cleaning device does not respond to the turning of the screw, the cleaning device
is depressurised
If the cleaning device responds to the turning of the screw, the cleaning device is still
connected to a compressed air supply.
If this is the case, you must disconnect the cleaning device from the compressed air
supply and check again that the cleaning device is depressurised before starting work
Briefly turn the "Lifting device up/down" screw on the cleaning device 90° to the right,
then turn it straight back to its original position
If the cleaning device does not respond to the turning of the screw, the cleaning device
is depressurised
If the cleaning device responds to the turning of the screw, the cleaning device is still
connected to a compressed air supply.
If this is the case, you must disconnect the cleaning device from the compressed air
supply and check again that the cleaning device is depressurised before starting work