Care, maintenance and disposal
General
The cleaning device generally needs no maintenance. However, to keep the cleaning de-
vice in good working condition for years to come, several points on care and maintenance
must be observed.
Before each start-
-
up
-
-
-
-
-
Daily
NOTE!
Only use solvent-free cleaning products on the cleaning device.
-
Weekly
NOTE!
Only use solvent-free cleaning products on the parting agent container.
-
-
Every 6 months
Open the device and check the pneumatic valves for:
-
-
-
If necessary
Open the device and
-
-
Disposal
Dispose of in accordance with applicable national and local regulations.
Check fill level in parting agent container and top up if necessary
Check fill level in parting agent spatter tray and empty if necessary
Check cleaning cutter for wear and replace if necessary
Empty the cleaning device spatter tray
If fitted, empty the wire cutter tray
Carry out a general visual inspection of the cleaning device and make sure that any
damage is repaired immediately (before start-up)
Remove parting agent deposits and dirt from device
Check the parting agent container for soiling and clean if necessary
Blow through the suction filter in the parting agent container using compressed air
from the inside outwards through the suction hose (see "Starting up the parting agent
nebuliser")
leaks
the secure seating of all screws
the secure seating of all screw joints on the pneumatic valves
clean the inside of the device using dry reduced compressed air
lightly oil the lifting device cylinder guides
85