Checking the Robacta Reamer V Easy and Robacta
Reamer V Easy Han6P J functions
General
NOTE!
Before starting the automatic cleaning process, the functions of the cleaning device
must be checked manually.
NOTE!
To ensure that the functions are checked properly, the welding torch must be in the
cleaning position.
Manually check-
NOTE!
ing the Robacta
Reamer V Easy
Functions are deactivated if the slot on the "Cleaning" screw is horizontal.
and Robacta
Reamer V Easy
Han6P J func-
tions
1
2
The following must be checked when the functions are being performed:
-
-
-
-
1
3
Lifting device up/down, Clamp gas nozzle/Cleaning
motor on, Spray in parting agent
Disconnect the cleaning device from the robot control
Establish a compressed air supply to the cleaning device
how far the cleaning cutter is inserted into the gas nozzle
function of the gas nozzle clamping device
function of the cleaning motor
parting agent emerging from the parting-agent injection nozzle
2 2
1 1
0 0
2
4
1 1
Deactivating the functions
1 1
67