Leica TPS400 Series User Manual page 45

Hide thumbs Also See for TPS400 Series:
Table of Contents

Advertisement

Enter offset values!
Trav.
Offset:
Length Offset:
Height Offset:
Mode
:
Reset after REC
RESET
Procedure:
1. Enter the offset values (length, cross and/or
height) as per the sketch.
2. Define the period for which the offset is to be
applied.
[RESET]: Sets eccentricity to zero.
3. [SET]: calculates the corrected values and
jumps to the application from which the offset
function was started. The corrected angle and
distances are displayed as soon as a valid
FNC Key
0.600 m
0.800 m
0.500 m
CYLNDER
OK
distance measurement has been triggered or
exists.
The period of applicability can be set as follows:
Reset after REC
Permanent
The offset values are always reset to 0 when
the application is quit.
Cylinder Offset subapplication
Use [CYLNDER] to determine the coordinates of the
centre point of cylindrical objects and their radius.
Measure the horizontal angle to a point on the left
and on the right side of the object as well as the
distance to the object.
45
The offset values are reset to 0
after the point is saved.
The offset values are applied to all
further measurements.
TPS400-5.0.1en