Procedure:
1. Measure to first prism (P1).
[All]
Starts measurement and proceeds
to step 2.
[ROD]
Allows you to define the rod and the
EDM-Settings.
Rod Length
Total length of hidden-point rod.
Dist. R1-R2
Spacing between the centers of reflector R1 and
prism R2.
Meas. Tol
Limit for the difference between the given and
measured spacing of the reflectors. If the tolerance
value is exceeded, the program will issue a warning.
EDM-Mode
Changes the EDM-Mode.
Prism type
Changes the prism type.
Prism Const
Displays the prism constant.
FNC Key
2. [All]
Starts measurement and proceeds
to the Result dialog.
3. Result is displayed.
HIDDEN POINT RESULT
PtID
:
Desc.
:
East
:
North
:
Heigth
:
FINISH
[NEW]
Returns to step 1.
[FINISH]
Returns to calling application.
49
12
GR
110.871 m
99.991 m
102.884 m
NEW