External supply
(via serial interface)
............................. If an external cable is used,
........................ then the voltage range must lie
..................................between 11.5V and 14V.
No. of measurements (angle + distance)
•
GEB111: ..................................... approx. 4000
•
GEB121: ..................................... approx. 9000
Temperature range
Operating
Type
temperature
-20°C to +50°C /
TPS400
-4°F to +122°F
-20°C to +50°C /
Battery internal
-4°F to +131°F
Automatic corrections
•
Line-of-sight error.......................................Yes
•
Vertical-index error.....................................Yes
•
Earth curvature ..........................................Yes
•
Refraction...................................................Yes
•
Tilt correction .............................................Yes
Technical Data
Recording
•
•
Storage
temperature
-40°C to +70°C /
-40°F to +158°F
-40°C to +55°C /
-40°F to +131°F
145
RS232 interface ......................................... Yes
Internal Memory ........................................ Yes
Total capacity....................................... 768 KB
.............................. ≈ 12500 measurements or
............................................. ≈ 18000 fixpoints
TPS400-5.0.1en