To access the SPECIAL FUNCTIONS Menu (SET UP Fx) push the SPECIAL FUNCTIONS (F
PARAMETER DISPLAY S
CREEN
ENCODER K
- A
NOB
PARAMETER DISPLAY S
CREEN
ENCODER K
- V
NOB
SPECIAL FUNCTIONS (F
) K
X
EY
SPECIAL FUNCTIONS (F
) LED
X
The SPECIAL FUNCTIONS (Fx) related to the MIG-MAG synergic, MIG pulsed, MIG double pulsed, Vision.PIPE, Vision.COLD,
Vision.POWER, and Vision.ULTRASPEED processes, correspond to the feeder (when fitted) as follows:
Special function
PRE GAS
STARTING SPEED
HOT START
STITCH TIME
STITCH PAUSE
SPOT TIME
INITIAL CURRENT
INITIAL ARC LENGTH
INITIAL CRATER TIME
INITIAL SLOPE
FINAL SLOPE
"HT5" CONTROL PANEL (not used with DH 32 and VS 32)
ENCODER K
- A
NOB
- A
Displays the selected SPECIAL FUNCTION (Fx).
Used to select the various SPECIAL FUNCTIONS (Fx).
- V
Displays the value for the selected SPECIAL FUNCTION (Fx).
Used to change the selected SPECIAL FUNCTION (Fx) value.
Only enables entering and exit afterwards from the SPECIAL FUNCTIONS Menu (SET UP
Fx) on the HT5 panel and not on the DH/VS panel.
The operator must press the SPECIAL FUNCTIONS (SET UP F
included in the SPECIAL FUNCTIONS Menu (SET UP Fx).
PARAMETER DISPLAY
Screen - A
PrG
StS
Hot
F05
F06
F07
F08
F09
F10
F11
F12
PARAMETER DISPLAY Screen - V
0.1s
(0.0 - 2.0)s
0
-30 - +30
0
-30 - +30
1.0s
(0.1 - 20.0)s
1.0s
(0.1 - 20.0)s
3.0s
(0.1 - 20.0)s
20%
-50% - +100%
0
-30 - +30
1.0s
(0.0 - 20.0)s
1.0s
(0.0 - 20.0)s
1.0s
(0.0 - 20.0)s
10
) K
.
X
EY
PARAMETER DISPLAY S
CREEN
ENCODER K
- V
NOB
SPECIAL FUNCTIONS (F
) K
X
SPECIAL FUNCTIONS (F
) LED
X
) K
for it to light up and be
X
EY
Welding mode
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
● (*) ● (*)
●
●
●
●
●
- V
EY
Table A
●
●
●
●
●
●
●
●
●
●
●
●
●
● (*) ● (*)
●
●
●
●
(continued)
Need help?
Do you have a question about the DIGITECH vision PULSE 3200 and is the answer not in the manual?
Questions and answers