15.3 Parameters for Welding Current Calibration Function
15.3 Parameters for Welding Current Calibration Function
The following tables show the parameters which are used for the welding current calibration
function.
Parameters used when the user file No.1 is selected
Display No.
P62
Current output characteristic 1
P63
Current output characteristic 2
C13
Current calibration
Reference current 1 (File No.1)
C14
Current calibration
Reference current 2 (File No.1)
Parameters used when the user file No.2 is selected
Display No.
P62
Current output characteristic 1
P63
Current output characteristic 2
C15
Current calibration
Reference current 1 (File No.2)
C16
Current calibration
Reference current 2 (File No.2)
Parameters used when the user file No.3 is selected
Display No.
P62
Current output characteristic 1
P63
Current output characteristic 2
C17
Current calibration
Reference current 1 (File No.3)
C18
Current calibration
Reference current 2 (File No.3)
Item
Initial Value
100
100
150
250
Item
Initial Value
100
100
150
250
Item
Initial Value
100
100
150
250
15-6
Content
Compensation ratio 1 for wire feed-
ing speed (Unit: %)
Compensation ratio 2 for wire feed-
ing speed (Unit: %)
Reference current 1 for the user file
No.1 (Unit: A)
Reference current 2 for the user file
No.1 (Unit: A)
Content
Compensation ratio 1 for wire feed-
ing speed (Unit: %)
Compensation ratio 2 for wire feed-
ing speed (Unit: %)
Reference current 1 for the user file
No.2 (Unit: A)
Reference current 2 for the user file
No.2 (Unit: A)
Content
Compensation ratio 1 for wire feed-
ing speed (Unit: %)
Compensation ratio 2 for wire feed-
ing speed (Unit: %)
Reference current 1 for the user file
No.3 (Unit: A)
Reference current 2 for the user file
No.3 (Unit: A)
HW0480311
HW0480311
116/129

Hide quick links: