14.2 Procedure of External Resistance Calibration

The following outlines how to calibrate the external resistance. For details, refer to the
following sections.
1. Connect the cable for resistance measurement. (Refer to " 14.2.1 Connecting the
Cable for Resistance Measurement ".)
2. Measure the external resistance value and confirm the display. (Refer to " 14.2.2 Mea-
suring the External Resistance Value " and " 14.2.3 Display of External Resistance
Setting Parameter ".)
3. Set the D parameter for calibration of the external resistance to "enabled." (Refer to "
14.2.4 Setting the D Parameter for Calibration of External Resistance to "Enabled" ".)
14.2.1
Connecting the Cable for Resistance Measurement
• Use a machine tool, etc. to securely tighten the connecting section of
the cable for resistance measurement. Since approx. 300 A current
flows at measurement of the external resistance, excessive heat gener-
ation may damage the devices in case of insufficient tightening.
• After moving the manipulator for connection of the cable for resistance
measurement, be sure to turn OFF the power supply of the robot control-
ler.
Unexpected motion of the manipulator during measurement may result in equipment
damage or personal injury.
14.2 Procedure of External Resistance Calibration
CAUTION
14-2
HW0480311
105/129