Adjustment Of Current Output - YASKAWA YWE-EH500-6N0 Instruction Manual

Table of Contents

Advertisement

HW0480311
13.7 Adjustment of Current Output Characteristics
Parameter
No.
Welding current output characteristic 1
(150 A or less: default setting)
Changes the wire feeding amount so
P62
that the real welding current value corre-
sponds to the welding current com-
mand.
Welding current output characteristic 2
(250 A or more: default setting)
Changes the wire feeding amount so
P63
that the real welding current value corre-
sponds to the welding current com-
mand.
The welding current output can be adjusted by setting parameters P62 and P63. The change
in the welding current output includes checking the welding current command against the
welding current that is fed back.
For welding current output characteristics, use the welding current calibration function than
setting the value of parameters P62 and P63.
Compensation by
the parameter P62
P62
Calibration current 1
E.g. 150 A
13.7 Adjustment of Current Output Characteristics
Meaning
Interpolation between
calibration points 1 and 2
Calibration current 2
E.g. 250 A
13-10
Guideline of Adjustment
- When real welding current value is
higher than the welding current com-
mand: Decrease the value.
- When real welding current value is lower
than the welding current command:
Increase the value.
- When real welding current value is
higher than the welding current com-
mand: Decrease the value.
- When real welding current value is lower
than the welding current command:
Increase the value.
Compensation by
Wire feeding amoutn
the parameter P63
after the compensation
P63
Wire feeding amount
before the compensation
Welding current command
(Panel display current)
HW0480311
103/129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motoweld-eh500

Table of Contents