12.2 Confirmation of DIP Switch Set Status
By referring to the information: "d-1" to "d-4" which is displayed in the Diagnosis mode, the
setting status of DIP switch on the PR(CR)-008 board of welding source inside can be
confirmed without removing the cover of the welding source.
For displaying the DIP switch status, ON/OFF state of each switch is displayed with 0/1 bit
data.
ON/OFF state of each switch : 1=ON / 0=OFF
The figure " Fig. 20 Display of DIP Switch Set Status " shows that the switches No.2, 3, and 6
of DSW3 are ON.
NOTE
If the display of Diagnosis mode is different from the actual DIP switch setting, there may
be failure on the Pr(CR) board or Pr(MB) board. Replace the board.
Fig. 19 DIP Switch of MOTOWELD-EH500
DSW No. : 1 to 4
8
7
Fig. 20 Display of DIP Switch Set Status
12-3
12.2 Confirmation of DIP Switch Set Status