Installation

Installing the Tank Strainer

A3EN-04-[3V-A-AAXP]-12
This procedure describes how to install the tank strainer on Series 3000V
units that have tank strainers. The following units have tank strainers:
Series 3100V
S
Series 3400V
S
Series 3500V
S
Series 3700V
S
The model number of each unit is listed on the front panel of the unit. If
your unit does not have a strainer, go to the next procedure, Connecting
the Air Supply. If it has a strainer, complete this procedure.
1. Locate the tank strainer that was shipped with your unit. If you have
a Series 3500V or Series 3700V unit, you will find two strainers.
2. Series 3500V and 3700V units only: See Figure A 1-3. Determine
the correct strainer to use for your adhesive, the small strainer or the
large strainer. If the solid adhesive form you plan to use is small
enough to pass through the holes in the strainers (both strainers have
the same size holes), use the large strainer. If the solid adhesive is
too large to pass through the holes, use the small strainer.
Fig. A 1-3
Small Strainer (left) and Large Strainer (right)
3. Remove all wrapping from the strainer. Small pieces of wrapping can
cause blockage in the pump.
4. Open the tank lid.
5. Place the strainer on the fins in the bottom of the tank. Position the
cutout in the strainer around the pump.
6. Close the tank lid.