Mechanical Installation; Mounting The Unit - Nordson 3000V Series Manual

Table of Contents

Advertisement

A 1-4
Installation

5. Mechanical Installation

Mounting the Unit

A3EN-04-[3V-A-AAXP]-12
This part of the installation section gives you the procedures for installing
the unit mechanically. It includes
Mounting the Unit
S
Installing the Tank Strainer
S
Connecting the Air Supply
S
Installing Guns
S
Installing Hoses
S
On some units, you will not be required to complete all of these
procedures. For electrical installation procedures, refer to Electrical
Installation later in this section.
Use this procedure to mount your unit.
1. Remove the bolts that secure the unit to the shipping pallet. Save the
bolts for later use.
2. For installation within the European Community, find the packet of
adhesive-backed, local-language warning tags that was shipped with
the unit. Overlay the non-English language part of the tags already
on this unit with the tags from the packet in your own language.
Carefully follow the instructions in the packet for the correct
placement of the tags.
WARNING: Take care when lifting the unit. Using inadequate
means to lift the unit can cause equipment damage, personal
injury, or both.
3. Using a suitable lifting device that is capable of lifting the unit, position
the unit on the mounting surface. To determine the weight of your
unit, refer to Specifications in the Description section of this manual.
4. Check to see that the unit is level. Provide shims as needed.
5. Using the unit's base as a guide, drill four holes in the mounting
5
surface for 8-mm (
/
16
41-3000V
Issued 5/00
-in.) mounting bolts.
E 2000 Nordson Corporation
All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3100v series3500v series3700v series3400v series

Table of Contents