E 2000 Nordson Corporation
All rights reserved
6. Press the Enter key (5) to save the setting. The display stops
flashing.
2
1
Fig. A 1-32
Using the Displays Keys to Set the Temperature of a Zone
(Displays Area)
1. Up key
2. Selector display
3. Multipurpose display
7. Record your setting in the forms provided at the end of this section.
Refer to Records of System Settings.
8. Press the Up key below the Selector display to select the next zone
number for the zone that you wish to customize, and repeat this
procedure until you have set temperatures for all zones.

To Program All Zones to the Same Temperature

Follow this procedure to set all zones to the same temperature. Also use
this procedure along with the procedure To Program Setpoint and
Standby Temperatures Individually to set most zones to the same
temperature.
NOTE: This procedure works only for zones that have been
previously turned on. The default setting for all zones is OFF. To turn
a zone on, refer to the previous procedure, To Program Setpoint and
Standby Temperatures Individually, and set the temperature of each
zone you want to turn on to at least 38 _C (100 _F).
1. If you have not already done so, turn power on to the unit by pressing
the POWER switch.
41-3000V
Issued 5/00
Installation
3
4
5
4. Up and Down keys
5. Enter key
A3EN-04-[3V-A-AAXP]-12
A 1-49
4103931