Defaults For Bead Start And End Points - Nordson 3000V Series Manual

Table of Contents

Advertisement

A 1-64
Installation
Programming a Pattern Set
(contd.)
A3EN-04-[3V-A-AAXP]-12
3. Check the Multipurpose display. The displays shows the default
setting for the bead start or end point. Refer to Table A 3-19.
Table A 1-19 Defaults for Bead Start and End Points
Start or End
Point
Time (ms)
Start point for
50 ms
first bead
End point for
100 ms
first bead
Start point for
150 ms
second bead
End point for
200 ms
second bead
4. Press the Up or Down key below the Multipurpose display to change
the current setting. The display flashes.
5. Press the Enter key to save the new setting. The Multipurpose
display stops flashing.
6. Repeat steps 2--5 until you have programmed all bead start and end
points for the pattern.
7. If you have a second pattern to apply to your product, repeat
steps 1--6 to program the bead start and end points for the
second pattern.
8. Go to the next procedure, Storing a Pattern Set.
NOTE: Although the system will allow you to use a pattern set as
soon as you program it, it is best to define and store all the pattern
sets you will need. If you use a pattern set you have not stored and
then you later program a new pattern set, the system will replace the
pattern you were using with the new pattern as you program it into the
system.
41-3000V
Issued 5/00
Default Setting
Distance (mm)
Distance (in.)
50 mm
5.0 in.
100 mm
10.0 in.
150 mm
15.0 in.
200 mm
20.0 in.
E 2000 Nordson Corporation
All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3100v series3500v series3700v series3400v series