To Program Setpoint and Standby Temperatures Individually

Follow this procedure to set the setpoint and standby temperatures for
each zone.
1. If you have not already done so, turn power on to the unit by pressing
the POWER switch.
2. In the System Setup area, press the Move Up and Move Down keys
until the SETPOINT or STANDBY light turns on. The system defaults
to the internal zone type and the INTERNAL light turns on.
NOTE: If you have enabled the password feature, you must change
the number in the Multipurpose display (500) to the password (321)
and press the Enter key before the system will allow you to change
any of the temperature setpoints.
3. If you want to select the hose-zone type or the gun-zone type instead
of the internal-zone type, press the Move Right key until the light
beneath the zone type you want to set turns on.
4. See Figure A 1-32. In the Displays area, press the Up key (1) below
the Selector display (2) until the zone number you want appears on
the display. (Refer to Table A 1-14.) The Multipurpose display (3)
changes to show the current temperature setting for the zone you
selected.
5. In the Displays area, press the Up or Down key (4) below the
Multipurpose display to change the temperature. The display flashes.
NOTE: Pressing the Up or Down keys in the Displays area once
changes the number shown in increments of one. Pressing and
holding the key changes the number in increments of five.
41-3000V
Issued 5/00
E 2000 Nordson Corporation