A 1-38
Installation
Closing the Electrical
Enclosure
7. System Programming
Procedures
TEMPERATURE
2
SETPOINT
1
STANDBY
INTERNAL
HOSE
SYSTEM
SETTINGS
CLOCK
SET TIME
ENTER
STANDBY
EXIT
STANDBY
HEATERS ON
INTERVAL
HEATERS OFF
1
PATTERN CONTROL
2
LINE
SPEED
STORE
USE
Fig. A 1-28
System Setup Area of the
Operator Panel
A3EN-04-[3V-A-AAXP]-12
After you have completed electrical installation, follow this procedure to
close the electrical enclosure.
1. Reconnect any ground wires that may have become disconnected
during electrical installation.
2. Raise the control-end frame into place and tighten the captive screws
on each side of the frame. You may need to pull the front and rear
panels apart to position the frame.
3. Position the electrical enclosure lid on top of the unit and secure it
with the captive screws.
4. Remove the lock-out and turn on the power at the branch circuit
disconnect switch.
Before running your unit, follow the procedures in this part of the
Installation section to program the unit for your operations. All
programming is done from the System Setup area of the operator panel.
From the System Setup area, you can program
how the unit operates (SYSTEM SETTINGS)
S
the temperature at which each zone operates (TEMPERATURE)
S
when the system operates (CLOCK)
S
GUN
the type of adhesive pattern applied to your product or package
S
(PATTERN CONTROL)
You will probably find it helpful to read Control System in the Description
section of this manual before programming any system controls. Control
System briefly describes the function of each control you will program.