Switching Frequency Derating; Output Frequency Derating; Cooling Characteristics, Noise, Dc Capacitance - ABB ACS880-104 Hardware Manual

Industrial drives, inverter modules
Hide thumbs Also See for ACS880-104:
Table of Contents

Advertisement

280 Technical data
Derating factor 0.85
Derating factor 0.80
For a more accurate derating, use the DriveSize PC tool.

Switching frequency derating

Switching frequencies other than default can require output current derating. Contact ABB
for more information.

Output frequency derating

Motor operation above 150 Hz can require type-specific output current derating. Contact
ABB for more information.

Cooling characteristics, noise, DC capacitance

Inverter unit
Power loss
type ACS880-
104-...
U
= 400 V
N
004A8-3
006A0-3
008A0-3
0011A-3
0014A-3
0018A-3
0025A-3
0035A-3
0044A-3
0050A-3
0061A-3
0078A-3
0094A-3
0100A-3
0140A-3
0170A-3
0210A-3
0250A-3
0300A-3
0350A-3
0470A-3
0640A-3
0760A-3
0900A-3
10000
1250A-3
13000
1480A-3
16000
1760A-3
20000
3
W
m
/h
70
24
80
24
90
24
110
48
140
48
170
48
200
142
300
142
350
200
410
200
500
290
600
290
740
290
750
290
1100
650
1400
650
1800
650
2000
650
2500
940
3100
940
4800
1300
6700
1300
8600
1300
1300
2600
2600
2600
Air flow
3
ft
/min
14
14
14
28
28
28
84
84
118
118
171
171
171
171
383
383
383
383
553
553
765
765
765
765
1530
1530
1530
Noise level
DC capacitance
dB(A)
μF
47
280
47
280
47
280
39
435
39
865
39
865
63
785
63
785
71
1178
71
1178
70
1570
70
2355
70
2355
70
2355
71
4500
71
4500
71
4500
71
6750
72
9000
72
9000
72
11250
72
13500
72
18000
72
18000
74
27000
74
36000
74
36000

Advertisement

Table of Contents
loading