Input Power (Dc) Connection; Motor (Ac) Connection - ABB ACS880-104 Hardware Manual

Industrial drives, inverter modules
Hide thumbs Also See for ACS880-104:
Table of Contents

Advertisement

Input power (DC) connection

Voltage (U
)
1
Drive AC supply network
type
Input terminals

Motor (AC) connection

Motor types
Voltage (U
)
2
Frequency (f
)
2
ACS880-104-xxxxx-3: 513...566 V DC. This is indicated in the type designation
label as typical input voltage level (566 V DC).
ACS880-104-xxxxx-5: 513...707 V DC. This is indicated in the type designation
label as typical input voltage levels (566/679/707 V DC).
ACS880-104-xxxxx-7: 709...976 V DC. This is indicated in the type designation
label as typical input voltage levels (742/849/976 V DC).
TN (grounded) and IT (ungrounded) systems up to 690 V AC, corner-grounded
systems up to 600 V AC
Frame R1i
UDC+, UDC–: 0.25...4 mm
PE: 1.5 N·m (13 lbf·in)
Frame R2i
UDC+, UDC–: 0.5 ... 6 mm
PE: 1.5 N·m (13 lbf·in)
Frames R3i, R4i and R5i
UDC+, UDC–: 6...70 mm
torque 4 N·m (30 lbf·in). Other conductor sizes can be used by replacing the original
lug with a suitable crimp ring terminal.
PE: Screw size M5, torque 3 N·m (25 lbf·in)
Connector cover screws: Torque 3 N·m (25 lbf·in)
Frames R6i and R7i
See chapter
Dimension drawings (page
a 400 mm wide Rittal VX25 enclosure (page 97)
Frame R8i and multiples
M12, maximum intrusion into module 20 mm (0.8"). See also chapter
drawings (page
339), and section
enclosure (page 110)
Asynchronous AC induction motors, permanent magnet synchronous motors and
AC induction servomotors
3-phase symmetrical, Umax at field weakening point:
ACS880-104-xxxxx-3: 0...400 V AC. The maximum value (400 V) is a typical drive
input voltage level shown on the type designation label of the supply unit corres-
ponding to 380...415 V AC.
ACS880-104-xxxxx-5: 0...400/480/500 V AC. The maximum values (400/480/500
V) are typical drive input voltage levels shown on the type designation label of the
supply unit corresponding to 380...500 V AC.
ACS880-104-xxxxx-7: 0...525/600/690 V AC. The maximum values (525/600/690
V) are typical drive input voltage levels shown on the type designation label of the
supply unit corresponding to 525...690 V AC.
0...500 Hz, except
0...120 Hz with sine output filters (option +E206)
0...120 Hz for frames R1i...R5i with du/dt filters (option +E205)
0...200 Hz for frames R6i and R7i with du/dt filters (option +E205)
For higher operational output frequencies, please contact your local ABB repres-
entative.
Operation above 150 Hz may require type-specific derating. For more information,
contact your local ABB representative.
, 0.5 ... 0.6 N·m (4.4 ...5.3 lbf·in)
2
2
, 1.2 ... 1.5 N·m (10.6 ... 13.3 lbf·in)
2
. Allen screw torque 15 N·m (11 lbf·ft), connection post
339), and section
One R8i module in a 400 mm wide Rittal VX25
Technical data 287
One R6i/R7i module in
Dimension