R1i...R4i modules in a 400 mm wide Rittal VX25 enclosure
A maximum of four frame R1i or R2i modules, or two frame R3i or R4i modules can be fitted
into a 400 mm wide VX25 enclosure, but the number can be reduced by optional equipment.
3
1
6
3
2
4
5
5
Cabinet construction 47
Description
Cubicle including:
1. DC input
2. DC switch/disconnector for all inverter modules
3. Main DC fuses
4. DC fuse disconnectors for each inverter module
5. Inverter modules
6. Air outlet with exhaust fan