Allowable Mounting Orientations - ABB ACS880-104 Hardware Manual

Industrial drives, inverter modules
Hide thumbs Also See for ACS880-104:
Table of Contents

Advertisement

282 Technical data
Inverter unit
Power loss
type ACS880-
104-...
009A8-7
014A2-7
0018A-7
0022A-7
0027A-7
0035A-7
0042A-7
0052A-7
0062A-7
0082A-7
0100A-7
0130A-7
0140A-7
0190A-7
0220A-7
0270A-7
0340A-7
0410A-7
0530A-7
0600A-7
0800A-7
12000
1030A-7
15000
1170A-7
18000
1540A-7
23000
1740A-7
26000
2300A-7
35000
2860A-7
43000
3420A-7
52000

Allowable mounting orientations

The modules must be mounted upright unless other orientations are expressly allowed
below.
Frames R6i...R7i: Installation on right-hand side (viewed from the front) allowed.
3
W
m
/h
280
280
400
280
490
280
580
280
660
280
860
280
1000
280
1120
280
800
650
1100
650
1300
650
1500
650
1800
650
2500
650
2800
940
3300
940
5200
1300
6100
1300
7900
1300
9000
1300
2600
2600
2600
3900
3900
5200
6500
7800
Air flow
3
ft
/min
165
165
165
165
165
165
165
165
383
383
383
383
383
383
553
553
765
765
765
765
1530
1530
1530
2295
2295
3060
3825
4590
Noise level
DC capacitance
dB(A)
μF
62
343
62
343
62
343
62
687
62
687
62
687
62
687
62
687
71
1500
71
1500
71
1500
71
3000
71
3000
71
3000
72
4500
72
4500
72
6000
72
6000
72
9000
72
9000
74
12000
74
18000
74
18000
76
27000
76
27000
76
36000
77
45000
78
54000

Advertisement

Table of Contents
loading

Table of Contents