Notes:
The wire size accepted by all screw terminals (for both stranded and solid wire) is 0.5 ...
2
2.5 mm
(24...12 AWG). The torque is 0.5 N·m (5 lbf·in).
1)
Current [0(4)...20 mA, R
selected by switch AI2. Change of setting requires reboot of control unit.
2)
Current [0(4)...20 mA, R
selected by switch AI1. Change of setting requires reboot of control unit.
3)
See section
The XD2D connector (page
4)
See chapter
The Safe torque off function (page
5)
Constant speed 1 is defined by parameter 22.26.
6)
0 = Acceleration/deceleration ramps defined by parameters 23.12/23.13 in use. 1 =
Acceleration/deceleration ramps defined by parameters 23.14/23.15 in use.
7)
Determines whether DICOM is separated from DIOGND (ie. common reference for digital
inputs floats; in practice, selects whether the digital inputs are used in current sinking or
sourcing mode). See also
ON: DICOM connected to DIOGND. OFF: DICOM and DIOGND separate.
8)
See section
DIIL input (page
9)
Total load capacity of these outputs is 4.8 W (200 mA at 24 V) minus the power taken by
DIO1 and DIO2.
= 100 ohm] or voltage [0(2)...10 V, R
in
= 100 ohm] or voltage [0(2)...10 V, R
in
306).
BCU-x2 ground isolation diagram (page
306).
Control units of the drive 301
> 200 kohm] input
in
> 200 kohm] input
in
313).
311). DICOM=DIOGND