Reference Data - Panasonic MA Motion Sensor Series Specification Sheet

Ma motion sensor series
Table of Contents

Advertisement

MA Motion Sensor (AMA1, AMB1, 2, 3)

REFERENCE DATA

Operating region characteristics
• How to interpret the graph
Example: Operating area of the Short Type
with rated detection distance of
8 cm
3.150
inch.
(1) Thin short type (AMA14
Short type (AMB14
Operating region for
rated detection distance
100
of 10 cm
3.937
90
3.543
80
3.150
70
Reflection board
2.756
200 × 200 mm
60
7.874 × 7.874 inch
2.362
(reflectivity: 90%)
50
Y
1.969
40
1.575
30
Reflection
1.181
board
20
.787
X
10
.394
0
20
0
.787
.787
10
10
.394
.394
Detection width W (mm inch)
DIMENSIONS
(Common to the Built-in oscillation circuit type and External triggering type)
1) Thin short type (V)
6.6
.260
*Rear side connector protrusion: Max. 0.4mm
3) Middle type (H)
19.35
.762
Receiver
Projector
5
.197
100
3.937
90
3.543
80
3.150
70
2.756
60
2.362
50
1.969
40
1.575
30
1.181
20
.787
10
.394
0
)
(2) Middle type (AMB24
)
800
3.937 inch
31.496
9 cm
3.534 inch
700
8 cm
3.150 inch
27.559
600
7 cm
2.756 inch
23.622
500
6 cm
2.362 inch
19.685
5 cm
1.969 inch
400
15.748
300
11.811
200
7.874
100
3.937
0
20
Stamped side
29.0
1.142
(one side only)
20.0
10.0
.787
.394
12.7
.500
11.0
.433
22
.866
3.1 dia.
.122 dia.
Connector surface
(Front lens surface)
Optical surface
31.2
1.228
23.1
14
.909
.551
0.4
29.5
.016
1.161
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Operating region for
rated detection
distance of 8 cm
3.150 inch
20
0
20
.787
.787
10
10
.394
.394
Detection width W (mm inch)
)
Operating region for
rated detection distance
of 80 cm
31.496 inch
70 cm
27.559 inch
60 cm
23.622 inch
Reflection board
50 cm
200 × 200 mm
19.685 inch
7.874 × 7.874 inch
(reflectivity: 90%)
40 cm
15.748 inch
Y
30 cm
11.811 inch
20 cm
Reflection
7.874 inch
board
X
40
20
0
20
40
.787
.787
1.575
30
10
10
30
1.181
.394
.394
1.181
Detection width W (mm inch)
2) Short type (H)
Operating area within the dotted lines
Objects that enter the entire area are detected.
Object
Operating area
within the dotted lines
Note: If only part of the object is in the detection area, it is not
detected.
Operating area within the solid lines
Objects that even partially enter the area are detected.
Object
Operating area
within the solid lines
(3) Long type (AMB34
2000
78.74
1750
68.898
1500
59.055
Reflection board
500 × 500 mm
1250
19.685 × 19.685 inch
49.213
(reflectivity: 90%)
1000
Y
39.37
750
29.528
Reflection
500
board
19.685
X
250
9.843
0
40
20
.787
1.575
30
10
1.181
.394
Detection width W (mm inch)
16
2.5 dia.
.630
.098 dia.
6.5
.256
16.25
.640
10
Connector surface
.394
(Front lens surface)
11
Optical surface
.433
Receiver
20
Projector
.787
4
.157
22.5
.886
)
Operating region for
rated detection distance
of 200 cm
78.74 inch
150 cm
59.055 inch
100 cm
39.37 inch
50 cm
19.685 inch
0
20
40
.787
10
30
.394
1.181
mm
inch
6
.236
19.5
.768

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ama1Amb1Amb2Amb3

Table of Contents