Data Bank Save Function - Panasonic LS-400 Series Operation Manual

Digital laser sensor
Hide thumbs Also See for LS-400 Series:
Table of Contents

Advertisement

7-3. Data Bank Save Function

This function saves amplifier settings.
Up to 3 sets of settings can be saved using '
You can select whether the settings for only one amplifier are saved or the settings for all amplifiers on the right
side that are connected via optical communication are saved all in a single step.
Saving one
amplifier only
Turn the Jog switch to select whether to save
settings for one amplifier or all amplifiers
in a single step.
Turn the Jog switch to select the
desired channel for saving.
Channel 1
The digital display will blink
to confirm the setting.
Ramco National
' '
Press the
MODE key 5 times.
Turn the Jog switch 3 times
toward the '
' direction.
Press the
Jog switch.
Turn the Jog switch once
toward the '
' direction.
Saving all amplifiers
in a single step
Press the
Jog switch.
* When saving only the
following one amplifier
Channel 2
Channel 3
Press the
Jog switch.
* When saving all amplifiers
in a single step
Press the
Jog switch.
The digital display
will scroll twice.
Press the
MODE key
The digital
once.
display will
blink to
confirm
Press the
the setting.
MODE key
once.
(800) 280-6933
' and '
' .
1Press the [MODE key] 5 times to select 'PRO mode'.
2Turn the [Jog switch] 3 times toward the '
select 'PRO3 mode'.
3Press the [Jog switch] to enter the 'data bank load setting'
state.
4Turn the [Jog switch] once toward the '
the 'data bank save setting' state.
5If the [Jog switch] is pressed, the current setting will be
displayed.
6Turn the [Jog switch] to select whether to save settings for
one amplifier or all amplifiers in a single step.
7If the [Jog switch] is pressed, the selected setting will be
confirmed.
8If the [Jog switch] is turned, the 'channel' will be changed.
Select the desired 'channel' for saving.
9If the [Jog switch] is pressed, the letters '
0If the [Jog switch] is pressed while '
settings will be saved to the selected 'channel'.
'
' (red) will quickly blink, and '
confirm the new setting.
If saving settings for all amplifiers in a single step, the display
will scroll twice and then the channels being saved will blink
(red) and the settings will be confirmed.
AIf the [MODE key] is pressed once, the amplifier will return to
'PRO3 mode'.
BPress the [MODE key] once, the amplifier will return to 'RUN
mode' (normal sensing operation).
40
' direction, to
' direction, to enter
' (red) will blink.
' (red) is blinking, the
' (red) will blink to
www.pansonicsensors.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls-401pLs-401-c2Ls-401