Run the following command from the host system console:
SETIOS HYPERPAV=XPAV
An example of the command is shown below:
SETIOS HYPERPAV=XPAV
IOS189I HYPERPAV MODE CHANGE INITIATED - CONTROL UNIT CONVERSION WILL
COMPLETE ASYNCHRONOUSLY
NOTE: You can set the SETIOS command for each logical partition (LPAR).

MIH timer value setting workflow

Set the MIH timer value for PAV operations. You can set the value at any time.
Procedure
1. During IPL, use the MIH parameter in the IECIOSxx parmlib member. Set the MIH timer value in
MVS/ESA or z/OS to 30 seconds.
2. Run the SETIOS system command.