Menu Structure Of Setting Mode - YOKOGAWA mR10000 436101 User Manual

Hide thumbs Also See for mR10000 436101:
Table of Contents

Advertisement

Common Operations and Menu Structure

Menu Structure of Setting Mode

24
References to the µ R10000 Recorder User's Manual (IM 04P01B01-01E) are given in
parentheses.
Range
CH
Volt
(section 5.1)
TC
RTD
1-5V
Scale
Delta
DI
SQRT
Skip
Bias
CH
Bias
(section 6.12)
Calibration
CH
Calibration
(section 6.13)
Alarm
CH
Level
(section 5.2)
Unit
CH
Unit
(section 5.3)
Chart
mm/h
(section 5.4)
Clock
(Date/Time)
(section 5.5)
Aux
Trend
(section 6.1)
Zone
(section 6.4)
Partial
(section 6.5)
Print out
(section 6.6)
Tag
(section 6.7)
Message
(section 6.8)
Chart 2
(section 6.9)
Moving_AVE
(section 6.3)
Filter
(section 6.2)
Alm delay T
(section 6.10)
Brightness
(section 6.11)
DST
(section 6.16)
Math
Formula
(section 9.2)
Unit
(section 9.3)
Constant
(section 9.4)
Alarm
(section 9.5)
TLOG
(section 9.6)
Aux
Batch
Batch No.
(section 6.14)
Lot No.
(section 6.14)
Detail
(section 6.14)
MSG format
(section 6.15)
Range
Span_L
Span_R
Range
Span_L
Span_R
Range
Span_L
Span_R
Span_L
Span_R
Scale_L
Type
Range
Span_L
Ref.CH
Span_L
Span_R
Range
Span_L
Span_R
Range
Span_L
Span_R
Bias
1 datums
1 revise
2 datums
Alarm
Type
Value
Relay
Mode
CH
Left
Right
CH
Partial
Expand
CH
Trend
Periodic
CH
Tag
Message No.
(Message)
mm/h
CH
No.of samples
CH
Resp.Time
CH
Duration
Display
Light
DST
Start month
Start day
CH
Mode
f.
Span_L
CH
Unit
No.
K##
CH
Level
Alarm
Type
CH
Timer No.
SUM scale
Zone
CH
Left
(section 9.7)
Partial
CH
Partial
(section 9.8)
Print out
CH
Trend
(section 9.9)
Tag
CH
Tag
(section 9.10)
Alm delay T
CH
Duration
(section 9.11)
Start
Comment
Print
Action
End
Comment
Print
Action
Start2
Same as Start.
End2
Same as End.
Message No.
(Message format)
Firmware version: 1.31
Scale_R
Low-cut
Span_R
Scale_L
Scale_R
Scale_L
Scale_R
Low-cut
2 revise
Decision
Relay_No.
Key operation
Hold down the MENU key for 3 seconds
in Operation mode to enter Setting mode.
:
Use the
:
Use the
Hold down the MENU key for 3 seconds
in Setting mode to return to Operation mode.
Boundary
Hold down both the
for 3 seconds in Setting mode to enter
Basic Setting mode.
are not displayed in the default
condition. To display these items,
settings must be changed in Basic
Setting mode.
Start time
End month
End day
Span_R
Value
Relay
Relay_No.
Right
Bound
Periodic
Line No.
(Comment)
Batch Name
Chart Speed
Clock
Date/Time
Feed
Line No.
(Comment)
Batch Name
Chart Speed
Clock
Date/Time
Feed
Auto inc.
POC output
Low-cut point
key.
key.
and
keys
End time
POC speed
IM 04P01B01-02E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents