Setup Items and Default Values
RS-422A/485 communication interface function (/C3 option).
Setup Item
RS-422/485 > Address
RS-422/485 > Baud rate
RS-422/485 > Data length
RS-422/485 > parity
RS-422/485 > Protocol
Ethernet communication interface function (/C7 option)
Setup Item
Ethernet > Host > Host
Ethernet > Host > Domain
Ethernet > Local IP > A
Ethernet > Local IP > M
Ethernet > Local IP > G
Ethernet > DNS > DNS
Ethernet > DNS > P
Ethernet > DNS > S
Ethernet > DNS > Suffix_P
Ethernet > DNS > Suffix_S
Ethernet > Login > Login
Ethernet > LoginSet > Level
Ethernet > LoginSet > Register
Ethernet > LoginSet > User
Ethernet > LoginSet > Password
Ethernet > Timeout > Timeout
Ethernet > Timeout > Duration
Ethernet > K. Alive > Keep alive
Calibration correction (/CC1 option)
Setup Item
Calibration > Channel
Calibration > Mode
Calibration > Point
Customized Menu
Setup Item
Cust. menu > Cust. menu
Cust. menu > Password
Cust. menu > P_Adj
Select menu > Set mode > Range
Select menu > Set mode > Bias
Select menu > Set mode > Alarm
Select menu > Set mode > Unit
Select menu > Set mode > Chart speed
Select menu > Set mode > Aux
Select menu > Set mode > Calibration
Select menu > Set mode > Math
Select menu > Set mode > Batch name
Select menu > Set mode > Batch detail
Select menu > Function > Manual print
Select menu > Function > Setup list
Select menu > Function > Message
Select menu > Function > Buffer clear
Select menu > Function > Periodic
54
Pen/Dot
Selectable Range or Selections
-
1 to 32
-
1200/2400/4800/9600/19200/38400
-
7/8
-
Odd/Even/None
-
NORMAL/MODBUS
Pen/Dot
Selectable Range or Selections
-
64 characters or less
-
64 characters or less
-
IP address
-
IP address (Subnet mask)
-
IP address (Default gateway)
-
On/Off
-
IP address (Primary DNS sever)
-
IP address (Secondary DNS sever)
-
Primary domain suffix
-
Secondary domain suffix
-
Use/Not
-
Admin/User1 to User6
-
On/Off
-
16 characters or less
-
4 characters or less
-
On/Off
-
1 to 120 min
-
On/Off
Pen/Dot
Selectable Range or Selections
-
01 to 06
-
Revise Value, Absolute Value
-
2 to 16
Pen/Dot
Selectable Range or Selections
-
Not/Use
-
Numbers and spaces within 4 digits
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
-
On/Off
Default Value
1
9600
8
Even
NORMAL
Default Value
Blank
Blank
0.0.0.0
0.0.0.0
0.0.0.0
Off
0.0.0.0
0.0.0.0
Blank
Blank
Not
Admin
Admin and User1
are On
Admin: admin
User1 to 6: user1 to
user6
Administrator: 0
User1 to 6: 1 to 6
Off
1 min
On
Default Value
01
Revise Value
2
Default Value
Not
Blank
Off
On
On
On
On
On
On
On
On
On
On
On
On
On
On
On
IM 04P01B01-02E