Menu Structure Of Setting Mode - YOKOGAWA VigilantPlant mR20000 Operation Manual

Hide thumbs Also See for VigilantPlant mR20000:
Table of Contents

Advertisement

Menu Structure of Setting Mode

Range
Bias
Calibration
Alarm
Unit
Chart
Clock
Aux
Math
Batch
IM 04P02B01-02E
References to the µ R20000 Recorder User's Manual (IM 04P02B01-01E) are given in
parentheses.
CH
Volt
(section 5.1)
TC
RTD
1-5V
Scale
Delta
DI
SQRT
Skip
CH
Bias
Bias
(section 6.12)
CH
Calibration
(section 6.13)
CH
Level
Alarm
(section 5.2)
CH
Unit
(section 5.3)
mm/h
(section 5.4)
(Date/Time)
(section 5.5)
Trend
(section 6.1)
Zone
(section 6.4)
Partial
(section 6.5)
Print out
(section 6.6)
Tag
(section 6.7)
Message
(section 6.8)
Chart 2
(section 6.9)
Moving_AVE
(section 6.3)
Filter
(section 6.2)
Alarm delay time
(section 6.10)
Brightness
(section 6.11)
DST
(section 6.16)
Formula
(section 9.2)
Unit
(section 9.3)
Constant
(section 9.4)
Alarm
(section 9.5)
TLOG
(section 9.6)
Aux
Batch No.
(section 6.14)
Lot No.
(section 6.14)
Detail
(section 6.14)
MSG format
(section 6.15)
Common Operations and Menu Structure
Range
Span_left
Span_right
Range
Span_left
Span_right
Range
Span_left
Span_right
Span_left
Span_right
Scale_left
Type
Range
Span_left
Ref.CH
Span_left
Span_right
Range
Span_left
Span_right
Range
Span_left
Span_right
1 datums
1 revise
2 datums
Type
Value
Relay
Mode
CH
Left
Right
CH
Partial
Expand
Boundary
CH
Trend
Periodic
CH
Tag
Message number
(Message)
mm/h
CH
Number of samples
CH
Response Time
CH
Duration
Display
Light
DST
Start month
Start day
CH
Mode
formula
Span left
CH
Unit
Nomber
K##
CH
Level
Alarm
Type
CH
Timer number
SUM scale
Zone
CH
Left
Right
(section 9.7)
Partial
CH
Partial
(section 9.8)
Print out
CH
Trend
(section 9.9)
Tag
CH
Tag
(section 9.10)
Alarm delay time
CH
Duration
(section 9.11)
Start
Comment
Line No.
Print
Batch Name
Action
Feed
End
Comment
Line No.
Print
Batch Name
Action
Feed
Start2
Same as Start.
End2
Same as End.
Message No.
(Message format)
Scale_right
Low-cut
Span_right
Scale_left
Scale_right
Scale_left
Scale_right
2 revise
Decision
Relay number
Key operation
Hold down the MENU key for 3 seconds
in Operation mode to enter Setting mode.
:
Use the
key.
:
Use the
key.
Hold down the MENU key for 3 seconds
in Setting mode to return to Operation mode.
Hold down both the
for 3 seconds in Setting mode to enter
Basic Setting mode.
are not displayed in the default condition.
To display these items, settings must be changed in
Basic Setting mode.
Start time
End month
End day
Span right
Value
Relay
Relay number
Boundary
Periodic
(Comment)
Chart Speed
Clock
Date/Time
(Comment)
Chart Speed
Clock
Date/Time
Auto inc.
POC output
Firmware version: 1.31
Low-cut
Low-cut point
and
keys
End time
POC speed
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

437101437102437103437104437106437112 ... Show all

Table of Contents