Sign In
Upload
Manuals
Brands
YOKOGAWA Manuals
Voice Recorder
mR10000 436103
YOKOGAWA mR10000 436103 Manuals
Manuals and User Guides for YOKOGAWA mR10000 436103. We have
2
YOKOGAWA mR10000 436103 manuals available for free PDF download: Manual, User Manual
YOKOGAWA mR10000 436103 Manual (272 pages)
Brand:
YOKOGAWA
| Category:
Voice Recorder
| Size: 15.66 MB
Table of Contents
Introduction
3
Recorder's Version and Functions Described in this Manual
4
About this Manual
5
Safety Precautions
5
Checking the Contents of the Package
8
How to Use this Manual
12
Conventions Used in this Manual
13
Table of Contents
15
Chapter 1 Functional Explanation and Setup Guide
19
Overview of the Recorder
19
Measuring Input Section
20
Alarms
25
Alarm Indication
27
Recording
31
Display
42
Computation Function (/M1 Option)
44
Fail/Chart End Detection and Output Function (/F1 Option)
47
Remote Control Function (/R1 Option)
48
Other Functions
50
Function Setup Guide
52
Recording Functions
53
Chapter 2 Before Using the Recorder
59
Handling Precautions
59
Installation
60
Installation Procedure
61
Input Signal Wiring
62
Optional Terminal Wiring
66
Chapter 3 Names of Parts and Run Operations
73
Names of Parts
73
Rear Panel
75
Installing or Replacing the Chart Paper
76
Installing/Replacing Felt Pens or Plotter Pen (Pen Model)
79
Switching the Display Screen
84
Printing Measured Values (Manual Printout)
85
Printing the Recorder Settings
86
Clearing the Alarm Printout Buffer
87
Printing Messages
88
Resetting the Report Data of the Periodic Printout
89
Releasing the Alarm Output (Alarm ACK Operation)
90
Activating/Releasing the Key Lock
91
Chapter 4 Common Operations for Setting Functions and Setup Menu App
93
Run Modes
93
Key Operations
94
Changing the Settings
95
Entering Characters
96
Index
97
Menu Structure, Settings, and List of Default Values
97
Setting the Input Range
107
Setting the Alarm
115
Setting the Unit on Scaled Channels
118
Changing the Chart Speed
119
Setting the Date/Time
120
Chapter 5 Frequently Used Setup Operations (Setting Mode)
107
Chapter 6 Setup Operations for Convenient Functions (Setting Mode)
121
Setting the Trend Recording Interval (Dot Model)
121
Setting the Filter (Pen Model)
123
Setting the Moving Average (Dot Model)
124
Setting Recording Zones for each Channel (Zone Recording)
125
Setting the Partial Expanded Recording
126
Turning Trend Recording (Dot Model) and Periodic Printout ON/OFF for each Channel
127
Setting Tags on Channels
128
Setting the Message String
129
Setting the Secondary Chart Speed (Remote Control Function, /R1)
130
Setting the Alarm Delay Duration
131
Setting the Brightness of the Display and Internal Light
132
Applying a Bias on the Measuring Input Signal
133
Performing Calibration Correction (/CC1 Option)
134
Setting up Start Printout and End Printout (/BT1 Option)
136
Setting the Message Format (/BT1 Option)
140
Setting the Date/Time When Switching between Standard Time and DST
142
Changing the Auxiliary Alarm Function
145
Changing the Integration Time of the A/D Converter
148
Setting the Burnout Detection Function of Thermocouples
149
Setting the RJC Function on Channels Set to TC Input
150
Changing the Channel Recording Color (Dot Model)
152
Recording by Compensating for the Pen Offset Along the Time Axis (Pen Model)
153
(Selecting the Channel/Tag Printout and Turning ON/OFF the Channel No., Alarm, Recording Start, New Chart Speed, Scale, and Pen Color Printouts)
154
Turning Printouts ON/OFF
154
Setting the Periodic Printout Interval and the Type of Data to be Printed
156
Setting the Bar Graph Display Mode
159
Setting the Key Lock Function
160
Enabling the Moving Average Function (Dot Model)
163
Enabling the Filter Function (Pen Model)
164
Enabling the Partial Expanded Recording Function
165
Changing the Display/Printout Language
166
Enabling the Bias, Low-Cut, Alarm Delay, Calibration Correction (/CC1 Option) Functions
167
Changing the Time Printout Format
169
Initializing the Settings
171
Assigning Functions to the Remote Control Input Terminals (/R1 Option)
172
Changing the Printout/Display Format of the Date
174
Selecting to Show/Hide the FUNC Key Menus
175
Selecting to Show/Hide Setting Mode Menus
177
Enabling/Disabling the Customized Menu
179
Setting the Calibration Correction Function (/CC1 Option)
182
Enabling Start Printout, End Printout, and Message Format (/BT1 Option)
184
Changing the Temperature Unit
186
Chapter 7 Setup Operations for Changing/Adding Functions (Basic Setting Mode)
145
Changing the Displayed Information
187
Chapter 8 Setup Operations for Changing the Displayed Contents
187
Key Operations for Changing the Displayed Information
187
Operations Related to the Computation Function (/M1 Option
191
Chapter 9 Operations Related to the Computation Function (/M1 Option)
192
Setting the Computing Equation
192
Setting the Constants Used in Equations
200
Setting the Alarm
201
Specifying the Timer Used in Statistical Calculations (TLOG)
203
Setting Recording Zones for each Channel (Zone Recording)
205
Setting the Partial Expanded Recording
206
Turning Trend Recording (Dot Model) and Periodic Printout (Including the Printout Using the TLOG Timer) ON/OFF for each Channel
207
Setting Tags on Channels
208
Setting the Alarm Delay Duration
209
Setting the Timer Used in TLOG Computation and Periodic Printout
210
Changing the Channel Recording Color (Dot Model)
213
Changing the Channel Assignments of Recording Pens (Pen Model)
214
Changing the Type of Report Data Printed in Periodic Printout
215
Setting the Bar Graph Display Mode
217
Setting the Procedure Taken When the Computed Result Is in Error
218
A List of Error Messages
221
Chapter 10 Troubleshooting
221
Warning Messages
223
Troubleshooting Flow Charts
224
Periodic Inspection
227
Cleaning the Recorder
228
Replacing the Internal Light LED
229
Calibrating the Recorder
230
Adjusting the Pen Position (Pen Model)
232
Adjusting the Dot Printing Position (Dot Model)
234
Recommended Replacement Periods for Worn Parts
236
Chapter 11 Maintenance
227
Chapter 12 Specifications
237
Input Specifications
237
Alarm Function Specifications
239
Recording Function Specifications
240
Display Function Specifications
243
Specifications of Optional Functions
249
General Specifications
254
Other Specifications
258
Dimensional Drawings
259
App
259
Periodic Printout and Printout Using the TLOG Timer (/M1 Option)
262
Appendix 1 Periodic Printout and Printout Using the TLOG Timer (/M1 Option)
266
Appendix 2 Periodic Printout Interval
266
Advertisement
YOKOGAWA mR10000 436103 User Manual (56 pages)
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 2.68 MB
Table of Contents
Table of Contents
2
Foreword
3
Safety Precautions
3
Handling Precautions
4
How to Use this Manual
4
Checking the Contents of the Package
5
Removing the Packing Materials
6
Recorder's Version and Functions Described in this Manual
7
Function Introduction/Names of Parts
8
Function Introduction
8
Names of Parts
9
Display and Key Panel
10
Installing/Wiring the Recorder
11
Installation Location
11
Installation Procedure
11
Input Signal Wiring
14
Optional Terminal Wiring
16
Power Supply Wiring
18
Common Operations and Menu Structure
20
Execution Modes
20
Operation Sequence
20
Key Operation
21
Menu Structure of Setting Mode
24
Menu Structure of Basic Setting Mode
25
Preparing to Record
26
Loading or Replacing the Chart Paper
26
Installing/Replacing Felt Pens (Pen Model)
28
Installing/Replacing the Plotter Pen (Pen Model)
29
Installing/Replacing the Ribbon Cassette (Dot Model)
29
Checking or Setting the Date/Time
31
Setting the Input Range and Alarm on Measurement Channels
32
Setup Example (1) of Thermocouple Input
32
Setup Example (2) of 1-5V Input and Unit
33
Setup Example (3) of 0 to 10 V Input and Unit
35
Setting the Alarm
38
Recording/Displaying Data
40
Starting the Recording
40
Stopping the Recording
40
Feeding the Chart Paper
40
Changing the Chart Speed
41
Viewing the Recorded Results
41
Description of the Printout Contents
42
Switching the Display Screen
44
Changing the Displayed Information
45
FUNC Key Operations in Operation Mode
46
Printing Measured Values (Manual Printout)
46
Printing the Recorder Settings
47
Clearing the Alarm Printout Buffer
48
Printing a Message
48
Releasing the Alarm Output (Alarm ACK Operation)
49
Activating/Releasing the Key Lock
49
Setup Items and Default Values
50
Setup Items in Setting Mode and Their Default Values
50
Setup Items in Basic Setting Mode and Their Default Values
52
Recommended Replacement Periods for Worn Parts
56
Advertisement
Related Products
YOKOGAWA mR10000 436102
YOKOGAWA mR10000 436101
YOKOGAWA mR10000 436106
YOKOGAWA mR10000 436104
YOKOGAWA MuR10000
YOKOGAWA VigilantPlant mR20000
YOKOGAWA MX112
YOKOGAWA MY600
YOKOGAWA MVAdvanced MV1004
YOKOGAWA Field Mate 3
YOKOGAWA Categories
Measuring Instruments
Test Equipment
Transmitter
Controller
Media Converter
More YOKOGAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL