AT commands
Parameter
1
2
Default
0

AO command

The API data frame output format for RF packets received.
Use AO to enable different API output frames.
Parameter range
0 - 2
Parameter
Description
0
API Rx Indicator - 0x90, this is for standard data frames.
1
API Explicit Rx Indicator - 0x91, this is for Explicit Addressing data frames.
Default
0

I/O settings commands

The following AT commands are I/O settings commands.

CB command

Use CB to simulate commissioning pushbutton presses in software.
Set the parameter value to the number of button presses that you want to simulate. For example,
send CB1 to perform the action of pressing the Commissioning Pushbutton once.
Parameter range
1, 4
Default
N/A

D0 (DIO0/AD0)

Sets or displays the DIO0/AD0 configuration (TH pin 20/SMT pin 33).
Parameter range
0 - 5
XBee S2C DigiMesh 2.4 User Guide
Description
API enabled
API enabled (with escaped control characters)