AT commands
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T5 (D5 Output Timeout)

Specifies how long pin D5 holds a given value (due to I/O line passing) before it reverts to configured
value. If set to 0, there is no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T6 (D6 Output Timeout)

Specifies how long pin D6 holds a given value (due to I/O line passing) before it reverts to configured
value. If set to 0, there is no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T7 (D7 Output Timeout)

Specifies how long pin D7 holds a given value (due to I/O line passing) before it reverts to configured
value. If set to 0, there is no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

T8 (D8 Timeout)

Specifies how long pin D8 holds a given value (due to I/O line passing) before it reverts to configured
value. If set to 0, there is no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0