5.2.6 Installing a Mezzanine Card

Procedure
Step 1 Power off the compute node.
For details, see
Step 2 Remove the compute node.
For details, see
Step 3 Place the compute node on the ESD workstation.
Step 4 Remove the cover.
For details, see
Step 5 Take the spare part out of its ESD bag.
Step 6 Determine the position of the mezzanine card.
Figure 5-9 Numbering and positions of mezzanine cards
Step 7 Install the mezzanine cards.
1.
2.
3.
Issue 06 (2019-08-10)
3.1 Power-Off
3.3 Removing a CH121
3.5 Removing the
Align the lower mezzanine card with the positioning holes and metallic studs on the
mounting base, and press the mezzanine card vertically downwards into the connector on
the mainboard. See (1) in
Tighten the two captive screws c and d (shown in
mezzanine card.
Align the upper mezzanine card with the positioning holes and metallic studs on the
mounting base, and press the mezzanine card vertically downwards into the connector on
the mainboard. See (2) in