Huawei FusionServer Pro CH121 V5 User Manual page 63

Compute node
Table of Contents

Advertisement

FusionServer Pro CH121 V5 Compute Node
User Guide
Step 8 Click OK.
Step 9 Observe the indicator status of the NVMe drive. If the green indicator is off and the yellow
indicator blinks at 0.5 Hz, remove the NVMe drive slowly.
For details about the drive indicator status, see
For details about how to manually remove an NVMe drive, see
Drive.
Step 10 Place the removed component in an ESD bag.
Step 11 Install a drive filler.
----End
Linux OS
Step 1 Determine the slot and position of the drive.
Figure 3-31 Positions of drives
Step 2 Check the running status of the drive by observing its indicators.
For details, see
Step 3 Determine whether the drive needs to be removed.
l
Issue 06 (2019-08-10)
NOTE
Perform this operation only when a drive is not installed immediately.
NOTE
Use the
Intelligent Computing Compatibility Checker
operating systems supported.
NVMe SSD
If yes, go to
Step
4.
Copyright © Huawei Technologies Co., Ltd.
NVMe SSD
Indicators.
3 Basic Operations
Indicators.
3.13 Removing a SAS/SATA
to obtain information about the Linux
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents